Xantrex RV2012 Manuel d'utilisateur Page 34

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 33
Xantrex RV Series Inverter/Charger Owner’s Manual
29
Troubleshooting Guide
Symptoms Problem Remedy
No power output and no
warning LEDs
Battery voltage at the inverter’s
terminals is too high or low
Check the battery voltage, fuses
or breakers and cable
connections
No power output and
LED indicator is flashing
Load too small for Search Mode
circuit to detect
Reduce search threshold setting
or defeat search mode
No power output and
warning LEDs “ON”
High or Low battery LED “ON” Check the battery voltage at
the inverter’s terminals
Overload LED is “ON” Remove loads from the
inverter and restart
High temp LED is “ON” Remove loads and let
inverter cool down before
restarting
Power output is low and
inverter turns loads on
and off
Low battery Check condition of batteries
and recharge if possible
Loose or corroded battery
connections
Check and clean all
connections
Loose AC output connections Check all AC output
connections
Inverter clicks every 20
seconds
Output of inverter wired back to its
own input
Check for proper AC input and
output wiring
Charger is inoperative or
Overload LED is “ON”
AC input voltage does not
match inverter spec
Check AC input for proper
voltage and frequency of
your model
Charger controls improperly
set
Refer to owner’s manual for
proper setting
Overload LED “ON”
while charging
Charger circuit may be damaged Have inverter serviced
Low charge rate
Low peak AC input
voltage(164 volts peak
required for full charger output)
Use larger generator, speed
up generator, check AC
input wiring size, adjust
charge rate, cable too small
or too long
AC current output of generator
too small to handle load
Reduce charge amps
setting or reduce pass-
through loads
Low AC output voltage Measuring with the wrong type
voltmeter (displays 80–100 VAC)
Voltmeter must be a true RMS
reading meter (most are not)
Low surge power Weak batteries, battery cables too
small or too long
Refer to cable and battery
recommendations in owner’s
manual
AC Lights flicker while
charging
Generator is unstable—charger is
losing synchronization
Turn battery charger rate down
until problem is gone
Vue de la page 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 43 44

Commentaires sur ces manuels

Pas de commentaire