Xantrex FREEDOM SW 3000 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Chargeurs de batterie Xantrex FREEDOM SW 3000. Xantrex FREEDOM SW 3000 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 86
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
TM
TM
Freedom SW 3000
Sine Wave Inverter/Charger
Owner’s Guide
FREEDOM SW
3000
I
n
v
e
r
ter
R
e
set Enable
I
nv
e
r
t
er
AC/
On
C
ha
r
ge
Fault
X
anbus
In
t
er
fac
e
FREEDOM SW
3000
I
n
v
er
ter
R
eset Enable
I
n
v
e
r
t
er
A
C/
On
C
ha
r
ge
Fault
X
anbus I
n
t
e
r
fa
c
e
Date
of Manufacture
Serial Number
CAUTION:
To reduce the risk of fire, do not
cover or obstruc
t ventilation openings. Do not mount
in a zero-clearance compartment. Overhea
ting may
result. Do not e
xpose to rain or spray.
INSTALLATION REQUIREMENTS:
Mount this inv
erter/charger only in the orientations
specified in the inst
allation g
uide provided.
WARNING:
Shock hazard. Do not open. No
user serviceable parts. Energized from both AC and
DC sources. Disconnect all
sources before servicing.
Use only ground-fault circuit interrupters (GFCI)
specified in the installation guide supplied. Other
types may fail to operate properly when connected to
this equipment. Refer to ma
nual. Charge only
lead-acid batteries. Other ba
ttery types may burst
causing personal injury and damage.
Nominal DC Operating Voltage:
12 Vdc
Nominal AC Output Voltage:
120 Vac , 1Ø
Nominal AC Output Frequency:
60 Hz
Max. Continuous AC Output Current:
25 A
Max. Operating DC Input Current:
320 A
Max. Continuous AC Output at Nominal DC
Input: 3000 VA at 25°C
Max. Output Surge Power (5 s duration): 6000 VA
Max. DC Input Voltage:
16 Vdc
Max. Ambient Temperature:
50°C
Inverter Mode:
Nominal AC Input Voltage:
120 Vac , 60 Hz, 1Ø
Power Factor:
> 0.95
Charging DC Output Voltage Range: 5.0 - 16.0 Vdc
Max. Continuous Battery Charger DC Current at
Nominal AC Input: 150 A
Max. AC Input Current:
30 A per line Split Phase,
30 A per line Dual
Charger Mode:
3000W SINEWA
VE INVE
R
TER/CHARGER
FSW3000
8
15-3000
Model
Number
FGA
Number
FREEDOM SW 3000
Designed in Canada
Assembled in China
DANGER:
To reduce the risk of explosion, do not
install in an area in
which igni
tion-protected
euipment is requi
red.
UL 45
8
CS
A 107.1
-01
3033614
FREEDOM SW
3000
FREEDOM SW
3000
Vue de la page 0
1 2 3 4 5 6 ... 85 86

Résumé du contenu

Page 1 - Sine Wave Inverter/Charger

TMTMFreedom SW 3000Sine Wave Inverter/ChargerOwner’s GuideFREEDOM SW 3000 Inverter Reset Enable Inverter AC/

Page 2

viii Freedom SW 3000 Owner’s GuideRegulatoryThe Freedom SW 3000 Inverter/Charger is certified to appropriate US and Canadian standards. For more infor

Page 3

Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 4 - About This Guide

On Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 5 - Related Information

Menu Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 6 - Important Safety Instructions

Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 7 - EXPLOSION HAZARD

975-0545-01-01 1IntroductionCongratulations on your purchase of the Freedom SW 3000 Inverter/Charger (Freedom SW 3000). The Freedom SW 3000 has been d

Page 8

2 Freedom SW 3000 Owner’s GuideIntroductionAbout the Freedom SW 3000Inverter/ChargerThe Freedom SW 3000 is a convenient combination of an inverter, mu

Page 9 - 975-0545-01-01 vii

975-0545-01-01 3IntroductionHow the Freedom SW 3000 Inverter/Charger WorksThe Freedom SW 3000 is designed to:• invert,•charge, and • accept both split

Page 10 - Regulatory

4 Freedom SW 3000 Owner’s GuideIntroductionLoad Management The Freedom SW 3000 has a built-in transfer relay that connects your inverter output or AC

Page 11 - Contents

975-0545-01-01 5IntroductionThe Xanbus-enabled designation means that this product works on a Xanbus network. Xanbus-enabled products are:• Easy to us

Page 13

6 Freedom SW 3000 Owner’s GuideFreedom SW 3000 Inverter/Charger FeaturesThis section describes the different parts of the Freedom SW 3000.Front and Si

Page 14

975-0545-01-01 7Freedom SW 3000 Inverter/Charger FeaturesFront and Side PanelsBefore you begin to operate the Freedom SW 3000, review the front panel

Page 15 - Introduction

8 Freedom SW 3000 Owner’s GuideFreedom SW 3000 Inverter/Charger FeaturesFigure 4Isometric View of the Front Panel and AC/DC Side PanelFREEDOM SW 30

Page 16 - Premium Power and Ease of Use

975-0545-01-01 9Freedom SW 3000 Inverter/Charger FeaturesAC and DC Side PanelsThe DC side of the Freedom SW 3000 has the equipment ground lug, the pos

Page 17 - Inverting

10 Freedom SW 3000 Owner’s GuideFreedom SW 3000 Inverter/Charger FeaturesSupplied AccessoriesNOTE: If any of the supplied accessories are missing, con

Page 18

975-0545-01-01 11Freedom SW 3000 Inverter/Charger FeaturesOptional System Accessories and Network ComponentsSystem accessories can be used with the Fr

Page 19 - 975-0545-01-01 5

12 Freedom SW 3000 Owner’s GuideOperating The Freedom SW 3000This section contains detailed information and procedures for using your Freedom SW 3000.

Page 20 - Figure 2

975-0545-01-01 13Operating The Freedom SW 3000Using the SCPAs shown in Figure 7, the SCP has these important features :Display screen System informati

Page 21 - FREEDOM SW 3000

14 Freedom SW 3000 Owner’s GuideOperating The Freedom SW 3000On Start UpWhen the Freedom SW 3000 is powered up or has been reset, all of the front pan

Page 22

975-0545-01-01 15Operating The Freedom SW 3000System Start-up CheckTo test inverting and charging from the Freedom SW 3000 front panel:1. Disconnect A

Page 23 - AC and DC Side Panels

975-0545-01-01 iAbout XantrexXantrex Technology Inc. (www.xantrex.com), a subsidiary of Schneider Electric, is a world leader in the development, manu

Page 24 - Supplied Accessories

16 Freedom SW 3000 Owner’s GuideOperating The Freedom SW 3000Operating in Invert ModeOnce the inverter/charger is installed, you can operate it in inv

Page 25 - Network Component Part Number

975-0545-01-01 17Operating The Freedom SW 3000Operating in Charger ModeNOTES:• Study and follow all of the battery manufacturer's specific precau

Page 26 - Operating The Freedom SW 3000

18 Freedom SW 3000 Owner’s GuideOperating The Freedom SW 3000When batteries are cold, their chemical reaction is sluggish, meaning they don’t absorb c

Page 27 - Using the SCP

975-0545-01-01 19Operating The Freedom SW 3000Follow the battery manufacturer’s recommendations for equalizing your batteries. As a guide, a heavily u

Page 28 - On Start Up

20 Freedom SW 3000 Owner’s GuideOperating The Freedom SW 3000Operating Limits for Charger OperationThe maximum output current for the Freedom SW 3000

Page 29 - System Start-up Check

975-0545-01-01 21Operating The Freedom SW 3000Monitoring the Freedom SW 3000 Indicator LightsThe ten indicator lights on the front panel show you the

Page 30 - Operating in Invert Mode

22 Freedom SW 3000 Owner’s GuideOperating The Freedom SW 3000System ModesThis section provides an overview of the two different system modes.The syste

Page 31 - Operating in Charger Mode

975-0545-01-01 23Operating The Freedom SW 3000SafeCharacteristics Selecting Safe mode stops the generator (if it is running) and puts the SCP (and all

Page 32 - RISK OF DAMAGE TO BATTERIES

24 Freedom SW 3000 Owner’s GuideOperating The Freedom SW 30004. Use the down arrow button to scroll through the other modes to select Safe mode.5. Pre

Page 33 - Equalizing Batteries

975-0545-01-01 25ConfigurationThis section contains information about all configurable settings and procedures for the Freedom SW 3000.It provides inf

Page 34

ii Freedom SW 3000 Owner’s GuideAbout This GuidePurposeThe purpose of this Owner’s Guide is to provide explanations and procedures for operating, trou

Page 35 - Faults and Warnings

26 Freedom SW 3000 Owner’s GuideConfigurationSystem Menu MapFigure 13 provides a map of how the SCP screens and menus are organized. The order of devi

Page 36 - System Modes

975-0545-01-01 27ConfigurationViewing the System ScreenThe System screen displays system activity. The information appearing on the System screen vari

Page 37 - 975-0545-01-01 23

28 Freedom SW 3000 Owner’s GuideConfigurationSelecting the Freedom SW 3000 from the Select Device MenuTo select the Freedom SW 3000 from the Select De

Page 38

975-0545-01-01 29ConfigurationTo select the Freedom SW 3000 Advanced Menu:1. On the Select Device menu with System highlighted, as shown in Figure 17,

Page 39 - Configuration

30 Freedom SW 3000 Owner’s GuideConfigurationReturning to Freedom SW 3000 Basic MenuYou can return to viewing the Freedom SW 3000 basic menu by select

Page 40 - SCP System Menu Map

975-0545-01-01 31ConfigurationMenu StructureAn overview of the Freedom SW 3000 menu structure is shown in Figure 20. The SCP displays the Freedom SW 3

Page 41 - Viewing the System Screen

32 Freedom SW 3000 Owner’s GuideConfigurationBatteryThe second line of the device screen indicates the status of the battery. This line displays the v

Page 42 - [*Enabled]

975-0545-01-01 33ConfigurationMenu (Basic)The Freedom SW 3000 basic menu indicates the status of items and lists settings that you may have to adjust

Page 43 - 975-0545-01-01 29

34 Freedom SW 3000 Owner’s GuideConfigurationYou can adjust the power share settings as follows:When to use Set the Power Share setting to match the A

Page 44 - Clear Faults

975-0545-01-01 35ConfigurationSelecting Yes takes you to the equalization system home screen, as shown in Figure 23.Table 5 provides an explanation of

Page 45 - Device Menu

975-0545-01-01 iiiRelated InformationYou can find more information about Xantrex Technology Inc. as well as its products and services at www.xantrex.c

Page 46 - AC Input1

36 Freedom SW 3000 Owner’s GuideConfigurationIf you choose Yes, the equalization process is cancelled and you are returned to the Freedom SW 3000 home

Page 47 - Menu (Basic)

975-0545-01-01 37ConfigurationBatt TypeFull name Battery TypeConfigurable setting Select the type of battery from flooded, custom, AGM, or gel. If a b

Page 48 - [Flooded]

38 Freedom SW 3000 Owner’s GuideConfigurationMenu (Advanced)The advanced menu lists settings that provide you with additional control over Freedom SW

Page 49 - 975-0545-01-01 35

975-0545-01-01 39ConfigurationSub-MenusConfigure Inv/Chg MenuCfg/Inv Chg is a sub-menu. If selected, the following list of sub-menu items appears.Max

Page 50 - Equalization?

40 Freedom SW 3000 Owner’s GuideConfigurationCfg AC Limits (Configure AC Limits)Cfg AC Limits is a sub-menu. If selected, a list of sub-menu items app

Page 51 - Batt Size

975-0545-01-01 41ConfigurationAC Limits (Configure AC Limits)Lo AC VoltFull name Low AC Transfer voltage (AC under voltage level)Configurable setting

Page 52 - Menu (Advanced)

42 Freedom SW 3000 Owner’s GuideConfigurationConfigurable setting This setting lets you adjust the voltage above which the inverter/charger no longer

Page 53 - Sub-Menus

975-0545-01-01 43ConfigurationView Device Info (View Device Information)If you select the View Device Info, the Freedom SW 3000 Device Info menu appea

Page 54

44 Freedom SW 3000 Owner’s GuideConfigurationRestore DefaultsConfigurable setting The Restore Default command restores the default settings for each d

Page 55

975-0545-01-01 45TroubleshootingIntroductionThe Freedom SW 3000 is designed for high reliability of operation and has a number of protection features

Page 56 - Hi AC Freq

iv Freedom SW 3000 Owner’s GuideImportant Safety InstructionsIMPORTANT: READ AND SAVE THIS OWNER’S GUIDE FOR FUTURE REFERENCE.This chapter contains im

Page 57 - View Warning Log

46 Freedom SW 3000 Owner’s GuideTroubleshootingWarning TypesThere are two types of warnings: automatic and manual. When the Freedom SW 3000 detects a

Page 58 - Restore Defaults

975-0545-01-01 47TroubleshootingTroubleshooting ReferenceThis chapter provides you with troubleshooting tips to identify and solve most problems that

Page 59 - Troubleshooting

48 Freedom SW 3000 Owner’s GuideTroubleshooting4. If your Freedom SW 3000 or SCP is not displaying a Fault light, check the following list to make sur

Page 60 - Warning Types

975-0545-01-01 49TroubleshootingWarning MessagesOnly Battery Low warning exists for the FSW3000. This warning will be recorded with a time stamp showi

Page 61 - Troubleshooting Reference

50 Freedom SW 3000 Owner’s GuideTroubleshootingFault MessagesWhen the Freedom SW 3000 detects a fault condition, the fault is displayed on the SCP and

Page 62

975-0545-01-01 51TroubleshootingTable 9 provides a detailed description of the fault messages and solutions. If you are unable to resolve the problem

Page 63 - Warning Messages

52 Freedom SW 3000 Owner’s GuideTroubleshootingF6 Too many AC loads. Turn some off, clear fault, try again.Escalating Auto Fault. Must occur 3 times i

Page 64 - Fault Messages

975-0545-01-01 53TroubleshootingF24 Inverter/Charger internal failure. Service required.Escalating Auto Fault. Must occur 3 times in 60 seconds before

Page 65 - 975-0545-01-01 51

54 Freedom SW 3000 Owner’s GuideTroubleshootingInverter ApplicationsThe Freedom SW 3000 performs differently depending on the AC loads connected to it

Page 66

975-0545-01-01 55Battery Charging ReferenceThis section describes the multistage charging algorithm (formula) of the Freedom SW 3000.Battery TypesFre

Page 67 - 975-0545-01-01 53

975-0545-01-01 vNOTES:1. Follow these instructions and those published by the battery manufacturer and the manufacturer of any equipment you intend to

Page 68 - Inverter Applications

56 Freedom SW 3000 Owner’s GuideBattery Charging ReferenceCharge Algorithm StagesThree-Stage chargingIf three-stage charging is enabled, the Freedom S

Page 69 - Battery Charging Reference

975-0545-01-01 57Battery Charging ReferenceEqualization Charge The equalization charge must be manually initiated from the SCP because it is not requi

Page 70 - Charge Algorithm Stages

58 Freedom SW 3000 Owner’s GuideBattery Charging ReferenceCharge Algorithm Graph Charge Algorithm DefinitionsFigure 27Three-Stage Charging ProfileIHIB

Page 71 - Two-Stage Charging

975-0545-01-01 59Battery Charging ReferenceThe numbers presented in these tables are base numbers only and will vary with factors such as temperature

Page 72 - (or wet) Gel AGM

60 Freedom SW 3000 Owner’s GuideBattery Charging ReferenceBattery Charger InterruptionIf battery charging is interrupted in bulk charge (for example,

Page 73

975-0545-01-01 61SpecificationsNOTE: Specifications are subject to change without prior notice.All inverter specifications are at nominal conditions:

Page 74 - Battery Charger Interruption

62 Freedom SW 3000 Owner’s GuideSpecificationsWithout a battery temperature sensorThree settings with the following temperature values:Cool 50 °F (10

Page 75 - Specifications

975-0545-01-01 63SpecificationsAll transfer specifications are at nominal conditions: ambient temperature of 77 °F (25 °C), 120 VAC, 60 Hz input, unle

Page 76 - Charger Specifications

64 Freedom SW 3000 Owner’s GuideSpecificationsInvert Power Derating vs. Ambient TemperatureThe inverter/charger delivers up to 3000 watts of sine wave

Page 77 - Fan Operation

975-0545-01-01 65Warranty and Return InformationWarrantyWhat does this warranty cover and how long does it last? This Limited Warranty is provided by

Page 78 - Charger Mode

vi Freedom SW 3000 Owner’s GuidePrecautions When Working With BatteriesNOTES:1. Mount and place the Freedom SW 3000 Inverter/Charger unit away from ba

Page 79 - Warranty

66 Freedom SW 3000 Owner’s GuideWarranty and Return InformationWhat proof of purchase is required? In any warranty claim, dated proof of purchase must

Page 80

975-0545-01-01 67Warranty and Return InformationDisclaimerProductTHIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED BY XANTREX IN CONNE

Page 81 - Disclaimer

68 Freedom SW 3000 Owner’s GuideWarranty and Return InformationReturn Material Authorization PolicyFor those products that are not being repaired in t

Page 82 - Out of Warranty Service

975-0545-01-01 69Warranty and Return InformationInformation About Your SystemAs soon as you open your Freedom SW 3000 Inverter/Charger package, record

Page 85

Xantrex Technology Inc.1 800 670 0707 Tel toll free1 408 987 6030 Tel direct1 800 994 7828 Fax toll [email protected]

Page 86 - Xantrex Technology Inc

975-0545-01-01 viiPrecautions When Preparing to ChargeNOTES:• Study and follow all of the battery manufacturer's specific precautions, such as re